12820
Coils and Transformers
TRANSFORMER,POWER
12820
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
3.30 ac volts nominal single component single secondary
-
Terminal Type And Quantity
6 pin
-
Frequency Rating
15.0 kilohertz nominal single component
-
Mounting Facility Quantity
1 single group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Body Outside Diameter
0.750 inches nominal
-
Reliability Indicator
not established
-
Maximum Operating Temp
85.0 deg celsius
-
Mounting Method
unthreaded hole single group
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Winding Operating Current
11.9 amperes ac maximum single component single primary
-
Winding Operating Voltage
10.00 ac volts nominal single component single primary
-
Inclosure Type
fully inclosed
-
Mounting Hole Diameter
0.119 inches nominal single group
-
Body Length
0.531 inches maximum
-
End Item Identification
1430-01-181-5884,battery command pos
-
Test Data Document
18876-11567767 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)