F1R12-A82-1060-001

Circuit Breakers

CIRCUIT BREAKER

F1R12-A82-1060-001

5925-01-256-3070

5925 - Circuit Breakers

Hsmv Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Surface To Terminal End Distance

    2.520 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac single location and 40.0 amperes dc single location

  • Body Width

    0.730 inches nominal

  • Trip Release Ambient Temp Rating

    70.0 deg fahrenheit nominal single location

  • Reset Method

    manual

  • Unpackaged Unit Weight

    2.300 ounces

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Bushing Length

    0.260 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    12.000 minimum at 200 pct single location and 80.000 maximum at 200 pct single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    un

  • Inclosure Protection Type For Which Designed

    corrosion resistant and fungus resistant

  • Case Material

    plastic

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Body Length

    1.260 inches nominal

  • Manual Actuator Type And Quantity

    1 push-pull

  • Pole Quantity

    1

  • Center To Center Distance Between Terminals Parallel To Length

    0.900 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...