2396609-2

Circuit Breakers

CIRCUIT BREAKER

2396609-2

5925-01-257-2887

5925 - Circuit Breakers

Lockheed Martin Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Body Width

    0.750 inches maximum

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac and 1000.0 dc single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct and 4.000 maximum at 200 pct single location

  • Frequency In Hertz

    50.0 or 60.0

  • Terminal Type And Quantity

    2 threaded stud

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Unpackaged Unit Weight

    3.700 ounces

  • Thread Series Designator

    unc

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Body Style

    12a single pole type

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.150 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac and 20.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and 50.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...