APL-112-6359-2

Circuit Breakers

CIRCUIT BREAKER

APL-112-6359-2

5925-01-257-4313

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Boss Height

    0.150 inches nominal

  • Mounting Surface To Terminal End Distance

    1.850 inches nominal

  • Body Length

    2.490 inches nominal

  • Body Width

    2.250 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and 50.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac and 1000.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    115.0 ac nominal third location

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    air

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac and 35.0 amperes dc all locations

  • Trip Release Method

    magnetic all locations

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip second location

  • Internal Trip Release Configuration

    series trip w/auxiliary load terminal and remote trip feature third location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Duty Cycle

    continuous third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.160 minimum at 200 pct and 1.600 maximum at 200 pct all locations

  • Special Features

    2 auxilliary trip coil terminals located at pole 3 only

  • Frequency In Hertz

    50.0 or 60.0

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    8 threaded stud

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip first location

  • Inclosure Protection Type For Which Designed

    dustproof

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...