366014-0001
Coils and Transformers
TRANSFORMER,PULSE
366014-0001
TRANSFORMER,PULSE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Outside Diameter
0.570 inches maximum
-
Body Length
0.585 inches maximum
-
Test Data Document
96214-366014 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Winding Operating Current
1.0 amperes maximum of standard range b single component single secondary
-
Inductance Rating
1.50 millihenries minimum single component single secondary
-
Reliability Indicator
not established
-
Peak Voltage Rating (Non-Core)
15.0 volts single component single primary
-
Mounting Method
terminal single group
-
Peak Voltage Rating (Non-Core)
15.0 volts single component single secondary
-
Maximum Operating Temp
130.0 deg celsius
-
Terminal Type And Quantity
5 pin
-
Impedance Rating In Ohms
10.0 nominal single component single secondary
-
Pulse Duration In Microseconds (Non-Core)
10.000 single component
-
Pulse Repetition Rate
50.0 kilohertz single component
-
Impedance Rating In Ohms
15.0 nominal single component single primary
-
Unpackaged Unit Weight (Non-Core)
9.8 grams
-
Winding Tap Location (Non-Core)
center tap single component single secondary
-
Mounting Bolt Circle Diameter
0.265 inches minimum single mounting facility single center group and 0.285 inches maximum single mounting facility single center group