2396610-1

Circuit Breakers

CIRCUIT BREAKER

2396610-1

5925-01-258-0489

5925 - Circuit Breakers

Lockheed Martin Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.240 minimum at 200 pct and 0.800 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac and 2000.0 dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and 50.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac and 20.0 amperes dc third location

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Boss Height

    0.140 inches minimum and 0.160 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.930 inches minimum and 1.950 inches maximum

  • Body Width

    2.230 inches minimum and 2.270 inches maximum

  • Terminal Type And Quantity

    6 threaded stud

  • Thread Series Designator

    unc

  • Special Features

    third pole includes a 115 vac auxilliary trip coil

  • Inclosure Protection Type For Which Designed

    general purpose

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Method

    magnetic all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac and 20.0 amperes dc second location

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac and 1.0 amperes dc first location

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    3

  • Mounting Surface To Terminal End Distance

    2.444 inches minimum and 2.506 inches maximum

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.657 inches minimum and 2.677 inches maximum

  • Case Material

    plastic

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Body Style

    8c multipole-multiple actuator type

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...