Technical Characteristics
-
~1
data on certain environmental and performance r
-
Test Data Document
81348-w-f-1814 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Specification/Standard Data
81348-w-f-1814/60 government specification
-
Features Provided
nonrenewable fusible element
-
Circuit Over-Current Interruption Type
time delay
-
Case Material
ceramic or fiber or plastic, melamine, glass filled
-
Body Style
axial terminal type
-
Overall Length
8.620 inches nominal
-
Short-Circuit/Interrupt Current Rating In Amps
200000.0
-
Overall Diameter
2.410 inches maximum
-
Maximum Voltage Rating In Volts
250.0 ac and 250.0 dc
-
Terminal Width
1.625 inches nominal
-
Mounting Slot Width
0.406 inches nominal
-
Terminal Material
copper or copper alloy
-
Body Length
4.625 inches minimum and 4.813 inches maximum
-
Circuit Over-Current Interruption Delay Time In Seconds
10.0 500 pct of current rating
-
Terminal Thickness
0.250 inches nominal
-
Continuous Current Rating In Amps
250.000
-
Interruption Indicator Method
opaque body