216556-4

Circuit Breakers

CIRCUIT BREAKER

216556-4

5925-01-259-3600

5925 - Circuit Breakers

Cubic Defense Applications Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    6.5 millimeters nominal

  • Body Length

    19.8 millimeters nominal

  • Body Width

    15.8 millimeters nominal

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    43.5 millimeters nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 dc single location

  • Trip Release Method

    thermal single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.375 inches

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    11.000 minimum at 200 pct single location and 60.000 maximum at 200 pct

  • Trip Release Ambient Temp Rating

    73.0 deg fahrenheit nominal single location

  • Switch Terminal Type

    quick disconnect, male

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Special Features

    marked 4 amps for training only

  • Thread Series Designator

    uns

  • Body Style

    1a single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    14.0 millimeters nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    27

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Inclosure Protection Type For Which Designed

    general purpose

  • Criticality Code Justification

    feat

  • Switch Current Rating And Type In Amps

    3.0 dc

  • Terminal Type And Quantity

    2 quick disconnect, male

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...