44-200-P10-SI-043.800-10

Circuit Breakers

CIRCUIT BREAKER

44-200-P10-SI-043.800-10

5925-01-259-3602

5925 - Circuit Breakers

Oakland Industries Ltd

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

  • Body Width

    15.8 millimeters nominal

  • Trip Release Ambient Temp Rating

    73.0 deg fahrenheit nominal single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Current Rating And Type In Amps

    3.0 dc

  • Switch Terminal Type

    quick disconnect, male

  • Trip Delay Time In Seconds Per Rated Continuous Current

    11.000 minimum at 200 pct single location and 60.000 maximum at 200 pct single location

  • Switch Location And Position Designation

    internal at pole one

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Inclosure Protection Type For Which Designed

    general purpose

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Mounting Surface To Terminal End Distance

    43.5 millimeters nominal

  • Internal Trip Release Configuration

    series trip single location

  • Center To Center Distance Between Terminals Parallel To Length

    14.0 millimeters nominal

  • Pole Quantity

    1

  • Bushing Length

    6.5 millimeters nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Thread Quantity Per Inch

    27

  • Manual Actuator Type And Quantity

    1 push-pull

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Special Features

    marked 10 amps for training only

  • Body Length

    19.8 millimeters nominal

  • Nominal Thread Size

    0.375 inches

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes dc single location

  • Actuator Function

    trip-reset

  • Criticality Code Justification

    feat

  • Actuator Position Designation

    at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...