216556-8

Circuit Breakers

CIRCUIT BREAKER

216556-8

5925-01-259-3603

5925 - Circuit Breakers

Cubic Defense Applications Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Manual Actuator Type And Quantity

    1 push-pull

  • Thread Quantity Per Inch

    27

  • Switch Contact Arrangement

    single pole, double throw

  • Bushing Length

    6.5 millimeters nominal

  • Pole Quantity

    1

  • Center To Center Distance Between Terminals Parallel To Length

    14.0 millimeters nominal

  • Internal Trip Release Configuration

    series trip single location

  • Mounting Surface To Terminal End Distance

    43.5 millimeters nominal

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    general purpose

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

  • Body Width

    15.8 millimeters nominal

  • Trip Release Ambient Temp Rating

    73.0 deg fahrenheit nominal single location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Current Rating And Type In Amps

    3.0 dc

  • Switch Terminal Type

    quick disconnect, male

  • Trip Delay Time In Seconds Per Rated Continuous Current

    11.000 minimum at 200 pct single location and 60.000 maximum at 200 pct single location

  • Switch Location And Position Designation

    internal at pole one

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 dc single location

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Actuator Position Designation

    at pole one

  • Criticality Code Justification

    feat

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes dc single location

  • Special Features

    marked 15 amps for training only

  • Nominal Thread Size

    0.375 inches

  • Body Length

    19.8 millimeters nominal

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...