W-C-375/19

Circuit Breakers

CIRCUIT BREAKER

W-C-375/19

5925-01-259-4730

5925 - Circuit Breakers

Federal Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Specification/Standard Data

    81348-w-c-375/19 government specification

  • Terminal Type And Quantity

    2 screw

  • Thread Series Designator

    unc

  • Frequency In Hertz

    60.0

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 maximum at 200 pct single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    thermal-magnetic single location

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Special Handling Feature

    magnetic

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    4.380 inches nominal

  • Case Material

    plastic

  • Body Height

    4.560 inches nominal

  • Body Length

    5.434 inches nominal

  • Body Style

    8a single pole type

  • Test Data Document

    81348-w-c-375 specification

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Nominal Thread Size

    0.138 inches

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Pole Quantity

    1

  • Body Width

    1.026 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...