6010632-021
Circuit Breakers
CIRCUIT BREAKER
6010632-021
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac first location
-
Reset Method
manual
-
Frequency In Hertz
400.0 first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location
-
Storage Type
general purpose warehouse
-
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac second location
-
Actuator Function
trip-reset
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac third location
-
Internal Trip Release Configuration
series trip all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.016 inches minimum and 1.036 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 minimum at 200 pct first location and 20.000 minimum at 200 pct third location and 20.000 minimum at 200 pct second location and 200.000 maximum at 200 pct first location
-
Trip Release Characteristic
time delay second location
-
Frequency In Hertz
400.0 second location
-
Inclosure Protection Type For Which Designed
dustproof and fungus proof
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Trip Release Characteristic
time delay third location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.740 inches minimum and 2.760 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
1.016 inches minimum and 1.036 inches maximum
-
Trip Release Characteristic
instantaneous fourth location
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac first location
-
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac third location
-
Frequency In Hertz
400.0 third location
-
Manual Actuator Type And Quantity
4 toggle
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac third location
-
Case Material
plastic
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac second location
-
Pole Quantity
4
-
Boss Height
0.210 inches minimum and 0.230 inches maximum
-
Body Style
multipole-multiple actuator type
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac second location
-
Trip Delay Time In Seconds Per Rated Continuous Current
200.000 maximum at 200 pct second location
-
Trip Release Characteristic
time delay first location
-
Center To Center Distance Between Terminals Parallel To Length
3.540 inches minimum and 3.560 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
200.000 maximum at 200 pct third location
-
Terminal Type And Quantity
8 threaded stud
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Nominal Thread Size
0.138 inches
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 dc fourth location
-
Body Width
4.144 inches maximum
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
8 threaded hole
-
Mounting Surface To Terminal End Distance
3.540 inches minimum and 3.560 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Length
4.740 inches minimum and 4.760 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc fourth location