M60AA-010S-24D

Relays and Solenoids

RELAY,ELECTROMAGNETIC

M60AA-010S-24D

5945-01-260-3789

5945 - Relays and Solenoids

Se Relays Llc Magnecraft

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Pattern

    in-line single mounting facility

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    2 slotted hole single mounting facility

  • Winding Quantity

    1

  • Case Material

    metal

  • Time Delay

    0.08 seconds nominal fixed release time

  • Cubic Measure

    44.301 cubic inches

  • Winding Dc Resistance Rating

    98.0 ohms nominal single winding

  • Overall Height

    5.063 inches maximum

  • Main Contact Load Current Rating At Maximum Rated Voltage

    17.0 amperes ac motor load and 3.7 amperes dc motor load

  • Terminal Type And Quantity

    6 screw all functions

  • Purpose For Which Designed

    general

  • Coil Quantity

    1

  • Mounting Slot Width

    0.188 inches nominal single mounting facility

  • Overall Length

    3.500 inches maximum

  • End Item Identification

    b-1bacftiate

  • Overall Width

    2.500 inches maximum

  • Operating Voltage Rating And Type At Specified Temp

    24.0 volts dc 25 deg celsius single winding

  • Duty Type

    continuous

  • Main Contact Load Current Rating At Maximum Rated Voltage

    60.0 amperes ac resistive load and 20.0 amperes dc resistive load

  • Main Contact Maximum Voltage Rating In Volts

    480.0 ac and 250.0 dc

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    2.280 inches nominal single mounting facility

  • Fragility Factor

    moderately rugged

  • Nominal Operating Current Rating And Type

    232.0 milliamperes dc single winding

  • Features Provided

    wetted contact

  • Nonpile-Up Main Contact Arrangement

    2 pole, single throw, normally open, momentary action

  • Time Delay

    0.05 seconds nominal fixed operate time

  • Storage Type

    general purpose warehouse

  • Environmental Protection

    hermetic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...