3D1117
Resistors
RESISTOR,THERMAL
3D1117
RESISTOR,THERMAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Zero Power Resistance Tolerance In Percent At Reference Temp
-10.0/+10.0
-
Zero Power Resistance At Specified Temp
3.19 kilohms 1st resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
50.0 deg celsius 3rd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-20.0/+20.0 1st resistance-temperature point
-
Body Width
0.070 inches nominal
-
Test Data Document
16224-985830 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Zero Power Resistance At Specified Temp
46.0 ohms 3rd resistance-temperature point
-
Body Outside Diameter
0.100 inches nominal
-
Zero Power Resistance
100.000 ohms
-
Terminal Length
1.000 inches minimum
-
Maximum Operating Temp
100.0 deg celsius
-
Style Designator
disk
-
Temp Points For Resistance Readings At Zero Power
0.0 deg celsius 2nd resistance-temperature point
-
Thermal Time Constant In Seconds
28.0
-
Ambient Temp At Full Rated Power
25.0 deg celsius
-
Terminal Type And Quantity
2 wire lead
-
Reliability Indicator
not established
-
Zero Power Resistance At Specified Temp
13.0 ohms 4th resistance-temperature point
-
Inclosure Type
encapsulated
-
Resistance Tolerance At A Specified Temp In Percent
-17.0/+17.0 4th resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
100.0 deg celsius 4th resistance-temperature point
-
Zero Power Resistance At Specified Temp
245.0 ohms 2nd resistance-temperature point
-
Power Dissipation Constant In Milliwatts Per Deg Celsius
8.0
-
Resistance Tolerance At A Specified Temp In Percent
-12.0/+12.0 2nd resistance-temperature point
-
Resistance Tolerance At A Specified Temp In Percent
-12.0/+12.0 3rd resistance-temperature point
-
Temp Points For Resistance Readings At Zero Power
-55.0 deg celsius 1st resistance-temperature point