216556-5

Circuit Breakers

CIRCUIT BREAKER

216556-5

5925-01-261-6359

5925 - Circuit Breakers

Cubic Defense Applications Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 60.000 maximum at 200 pct

  • Trip Release Ambient Temp Rating

    150.0 deg fahrenheit nominal single location

  • Switch Terminal Type

    quick disconnect, male

  • Switch Current Rating And Type In Amps

    1.0 ac and 5.0 dc

  • Switch Voltage Rating And Type In Volts

    220.0 ac and 28.0 dc

  • Body Style

    1a single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    12.7 millimeters nominal

  • Switch Contact Arrangement

    double pole, double throw

  • Pole Quantity

    1

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip single location

  • Thread Pitch In Millimeters

    1.25

  • Inclosure Protection Type For Which Designed

    general purpose

  • Criticality Code Justification

    feat

  • Special Features

    amps marked on item is for training only

  • Frequency In Hertz

    400.0 single location

  • Thread Series Designator

    iso m

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Bushing Length

    6.5 millimeters nominal

  • Body Length

    19.8 millimeters nominal

  • Body Width

    15.8 millimeters nominal

  • Case Material

    plastic

  • Mounting Surface To Terminal End Distance

    43.5 millimeters nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes ac single location and 100.0 milliamperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 28.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Nominal Thread Size

    12.0 millimeters

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...