216556-10

Circuit Breakers

CIRCUIT BREAKER

216556-10

5925-01-261-7872

5925 - Circuit Breakers

Cubic Defense Applications Inc.

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

  • Switch Current Rating And Type In Amps

    1.0 ac and 5.0 dc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Thread Pitch In Millimeters

    1.25

  • Trip Release Ambient Temp Rating

    150.0 deg fahrenheit nominal single location

  • Criticality Code Justification

    feat

  • Actuator Function

    trip-reset

  • Body Length

    19.8 millimeters nominal

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Bushing Length

    6.5 millimeters nominal

  • Pole Quantity

    1

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Contact Arrangement

    double pole, double throw

  • Thread Series Designator

    iso m

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 28.0 dc single location

  • Switch Voltage Rating And Type In Volts

    220.0 ac and 28.0 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 60.000 maximum at 200 pct single location

  • Special Features

    amps marked on item is for training only

  • Body Width

    15.8 millimeters nominal

  • Body Style

    single pole type

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Inclosure Protection Type For Which Designed

    general purpose

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Mounting Surface To Terminal End Distance

    43.5 millimeters nominal

  • Nominal Thread Size

    12.0 millimeters

  • Internal Trip Release Configuration

    series trip single location

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    12.7 millimeters nominal

  • Switch Terminal Type

    quick disconnect, male

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes ac single location and 100.0 milliamperes dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...