A3012900-1
Coils and Transformers
TRANSFORMER,AUDIO FREQUENCY
A3012900-1
TRANSFORMER,AUDIO FREQUENCY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Primary To Secondary Turn Ratio
1 to 1 to 1 single component
-
Inclosure Type
fully inclosed
-
Maximum Operating Temp
105.0 deg celsius
-
Reliability Indicator
not established
-
Mounting Method
terminal single group
-
Frequency Rating
150.0 hertz minimum single component and 75.0 kilohertz maximum single component
-
Test Data Document
80063-a3012900 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Body Outside Diameter
0.490 inches minimum and 0.510 inches maximum
-
Overall Length
0.520 inches nominal
-
Winding Tap Location (Non-Core)
center tap single component single primary
-
Impedance Rating In Ohms
135.0 minimum single component single primary and 165.0 maximum single component single primary
-
Terminal Type And Quantity
7 wire lead
-
Hazardous Locations/Environmental Protection
fungus resistant
-
End Item Identification
5895-01-188-8819 amplifier,adapter
-
Winding Operating Current
8.0 milliamperes maximum of standard range b and better drop siding single component single primary
-
Maximum Transformer Power Rating
1.0 watts single component
-
Body Length
0.500 inches maximum
-
Winding Function And Quantity
1 primary single component and 2 secondary single component