6790022-Q
Coils and Transformers
TRANSFORMER,POTENTIAL
6790022-Q
TRANSFORMER,POTENTIAL
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Direction
right-hand single group
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.410 inches nominal single mounting facility single center group
-
Frequency Rating
420.0 hertz maximum single component
-
Body Length
1.950 inches nominal
-
Body Height
1.900 inches nominal
-
Iii End Item Identification
6110-01-212-1076 panel,protection
-
Inclosure Type
fully inclosed
-
Thread Class
2b single group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.610 inches nominal single mounting facility single center group
-
Overall Width
1.000 inches nominal
-
Frequency Rating
380.0 hertz minimum and
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Iii Maximum Operating Temp
125.0 deg celsius
-
Mounting Facility Quantity
4 single group
-
Mounting Method
threaded hole single group
-
Nominal Thread Size
0.112 inches single group
-
Winding Operating Voltage
205.00 ac volts nominal single component single primary
-
Winding Operating Voltage
25.63 ac volts nominal single component single secondary
-
Winding Function And Quantity
1 primary and
-
Winding Function And Quantity
1 secondary single component
-
Winding Tap Location
neutral tap single component single primary
-
Special Features
three phase wye connection to three phase delta connection
-
Thread Series Designator
unc single group
-
Terminal Type And Quantity
8 turret