T14-S-SP-7413-1

Circuit Breakers

CIRCUIT BREAKER

T14-S-SP-7413-1

5925-01-264-2751

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.095 inches minimum and 1.155 inches maximum

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Body Length

    1.350 inches minimum and 1.400 inches maximum

  • Body Style

    single pole type

  • Thread Series Designator

    un

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 32.0 dc single location

  • Trip Release Duty Cycle

    continuous single location

  • Case Material

    plastic

  • Body Width

    0.670 inches minimum and 0.690 inches maximum

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.525 inches minimum and 1.585 inches maximum

  • Special Features

    includes 1/2x32 knurled nut,1/2 in. locking ring; vertical mount only

  • Terminal Type And Quantity

    2 wire lead and 2 threaded stud

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Pole Quantity

    1

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct single location and 2.000 maximum at 200 pct single location

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    18.0 dc nominal single location

  • Internal Trip Release Configuration

    series/relay trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Bushing Length

    0.458 inches minimum and 0.478 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...