48853 21050
Circuit Breakers
CIRCUIT BREAKER
48853 21050
Thales Defence & Security Systems
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Release Method
magnetic single location
-
Terminal Type And Quantity
2 wire hook
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Actuator Function
trip-reset
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Circuit Protection Type
overcurrent single location
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Pole Quantity
1
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Body Length
1.500 inches maximum
-
Trip Release Characteristic
time delay single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
~1
single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 maximum at 200 pct single location and 0.010 minimum at 400 pct single location and 4.000 minimum at 125 pct single location and 40.000 maximum at 125 pct single location and 0.850 minimum at 200 pct single location and 0.500 maximum at 400 pct
-
Bushing Length
0.380 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc single location
-
Thread Series Designator
unef
-
Mounting Surface To Terminal End Distance
1.605 inches maximum
-
Body Width
0.625 inches maximum
-
Body Style
single pole type
-
Ultimate Trip Time Per Pole In Seconds
0.010 minimum single location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location