80516-3

Circuit Breakers

CIRCUIT BREAKER

80516-3

5925-01-264-8885

5925 - Circuit Breakers

Hamilton Sundstrand Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Width

    1.490 inches minimum and 1.510 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.490 inches minimum and 1.510 inches maximum

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    explosion resistant and humidity resistant

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Thread Series Designator

    unc

  • Body Style

    4b multipole-single actuator type

  • Bushing Length

    0.235 inches minimum and 0.250 inches maximum

  • Body Height

    2.470 inches nominal

  • Body Length

    2.200 inches maximum

  • Body Width

    2.260 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.190 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.800 inches minimum and 1.820 inches maximum

  • Fragility Factor

    moderately rugged

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6000.0 ac all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Nominal Thread Size

    0.138 inches

  • Terminal Type And Quantity

    6 tab w/screw

  • Frequency In Hertz

    400.0 all locations

  • Unpackaged Unit Weight

    290.0 grams

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...