W-C-375/1

Circuit Breakers

CIRCUIT BREAKER

W-C-375/1

5925-01-265-7694

5925 - Circuit Breakers

Federal Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Body Style

    single pole type

  • Frequency In Hertz

    60.0 single location

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 maximum at 200 pct single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac single location

  • Case Material

    plastic

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac single location

  • Specification/Standard Data

    81348-w-c-375/1 government specification

  • Body Height

    2.580 inches nominal

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Body Width

    0.730 inches nominal

  • Mounting Facility Type And Quantity

    terminal

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Circuit Protection Type

    overcurrent single location

  • Terminal Type And Quantity

    1 clip and 1 screw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Pole Quantity

    1

  • Boss Height

    0.250 inches nominal

  • Body Length

    3.000 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Method

    thermal-magnetic single location

  • Trip Release Characteristic

    time delay single location

  • ~1

    data on certain environmental and performance re

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...