WC375/16-009

Circuit Breakers

CIRCUIT BREAKER

WC375/16-009

5925-01-265-7698

5925 - Circuit Breakers

Federal Specifications

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Trip Release Method

    thermal-magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Style

    single pole type

  • Body Length

    6.000 inches nominal

  • Frequency In Hertz

    60.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    5.062 inches nominal

  • Terminal Type And Quantity

    2 compression

  • Body Height

    3.375 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    360.000 maximum at 200 pct single location

  • Case Material

    plastic

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac single location

  • ~1

    data on certain environmental and performance re

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac single location

  • Mounting Slot Width

    0.094 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Body Width

    1.375 inches nominal

  • Mounting Facility Type And Quantity

    4 slot

  • Inclosure Protection Type For Which Designed

    dustproof

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac single location

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.500 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...