29-2727023-1

Circuit Breakers

CIRCUIT BREAKER

29-2727023-1

5925-01-267-1050

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    2a single pole type

  • Bushing Length

    0.495 inches nominal

  • Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Pole Quantity

    1

  • Body Length

    2.000 inches nominal

  • Case Material

    plastic

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Operating Voltage Type And Rating Per Pole In Volts

    56.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.500 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct and 150.000 maximum at 200 pct single location

  • Switch Terminal Type

    pin

  • Terminal Type And Quantity

    2 tab w/screw

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes dc single location

  • Trip Release Method

    magnetic single location

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    general purpose

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Thread Series Designator

    un

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...