34-2726975-1

Filters and Networks

FILTER,BAND PASS

34-2726975-1

5915-01-267-1059

5915 - Filters and Networks

General Dynamics C4 Systems Inc.

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reference Frequency Per Function

    70.0 megahertz 3rd band pass .

  • Source Impedance Rating Per Function

    50.0 ohms 3rd band pass .

  • Source Impedance Rating Per Function

    50.0 ohms 4th band pass .

  • Load Impedance Per Function

    50.0 ohms 1st band pass .

  • Load Impedance Per Function

    50.0 ohms 3rd band pass .

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th band pass

  • Mounting Facility Screw Thread Series Designator

    unc

  • Inclosure Type

    encased

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd band pass .

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 3rd band pass .

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 4th band pass .

  • Functional Terminal Type And Quantity

    4 pin ground .

  • ~1

    rtz 2nd band pass and 77.00 megahertz 2nd band pass .

  • ~1

    rtz 3rd band pass and 77.00 megahertz 3rd band pass .

  • ~1

    rtz 4th band pass and 77.00 megahertz 4th band pass .

  • Specified Frequencies Of Discrimination Per Function

    63.00 megahertz 1st band pass and 67.50 megahertz 1st band pass and 72.50 megahe

  • Specified Frequencies Of Discrimination Per Function

    63.00 megahertz 4th band pass and 67.50 megahertz 4th band pass and 72.50 megahe

  • Nominal Thread Size

    0.086 inches

  • Body Material

    metal

  • Frequency Band Width Per Function

    67.50 megahertz 4th band pass and 72.50 megahertz 4th band pass .

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    67.5 megahertz 2nd band pass and 72.5 megahertz 2nd band pass .

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    67.5 megahertz 4th band pass and 72.5 megahertz 4th band pass .

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st band pass .

  • Functional Terminal Type And Quantity

    4 pin input .

  • Functional Terminal Type And Quantity

    4 pin output .

  • Overall Height

    0.780 inches maximum

  • Body Length

    3.250 inches maximum

  • Body Width

    2.500 inches maximum

  • Body Height

    0.550 inches maximum

  • Vibration Resistance Range In Hertz

    10.0/ 200.0

  • Operating Temp Range

    -32.0/+70.0 deg celsius

  • Reference Frequency Per Function

    70.0 megahertz 1st band pass .

  • Reference Frequency Per Function

    70.0 megahertz 2nd band pass .

  • Reference Frequency Per Function

    70.0 megahertz 4th band pass .

  • Source Impedance Rating Per Function

    50.0 ohms 1st band pass .

  • Source Impedance Rating Per Function

    50.0 ohms 2nd band pass .

  • Load Impedance Per Function

    50.0 ohms 2nd band pass .

  • Load Impedance Per Function

    50.0 ohms 4th band pass .

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd band pass

  • Voltage Standing Wave Ratio Per Function

    2.0 1st band pass .

  • Voltage Standing Wave Ratio Per Function

    2.0 2nd band pass .

  • Voltage Standing Wave Ratio Per Function

    2.0 3rd band pass .

  • Voltage Standing Wave Ratio Per Function

    2.0 4th band pass .

  • Mounting Facility Type And Quantity

    4 threaded stud

  • ~1

    rtz 1st band pass and 77.00 megahertz 1st band pass .

  • Specified Frequencies Of Discrimination Per Function

    63.00 megahertz 2nd band pass and 67.50 megahertz 2nd band pass and 72.50 megahe

  • Specified Frequencies Of Discrimination Per Function

    63.00 megahertz 3rd band pass and 67.50 megahertz 3rd band pass and 72.50 megahe

  • Frequency Band Width Per Function

    67.50 megahertz 1st band pass and 72.50 megahertz 1st band pass .

  • Frequency Band Width Per Function

    67.50 megahertz 2nd band pass and 72.50 megahertz 2nd band pass .

  • Frequency Band Width Per Function

    67.50 megahertz 3rd band pass and 72.50 megahertz 3rd band pass .

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    67.5 megahertz 1st band pass and 72.5 megahertz 1st band pass .

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    67.5 megahertz 3rd band pass and 72.5 megahertz 3rd band pass .

  • Special Features

    5 unfiltered pin terminals

  • Style Designator

    2 rectangular terminal/terminals on one surface

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...