3614780
Circuit Breakers
CIRCUIT BREAKER
3614780
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Case Material
plastic
-
Switch Location And Position Designation
internal at pole one
-
Switch Current Rating And Type In Amps
4.0 ac and 2.5 dc
-
Switch Terminal Type
quick disconnect, male
-
Inclosure Protection Type For Which Designed
salt water resistant and shock resistant and moisture resistant and vibration resistant
-
Auxiliary Switch Function And Quantity
1 alarm
-
Body Width
0.735 inches minimum and 0.765 inches maximum
-
Trip Release Method
magnetic-hydraulic single location
-
Body Style
single pole type
-
Terminal Type And Quantity
2 quick disconnect, male
-
Thread Series Designator
iso s
-
Frequency In Hertz
50.0 single location or 60.0 single location
-
Actuator Position Designation
at pole one
-
Reset Method
manual
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
-
Center To Center Distance Between Terminals Parallel To Length
1.515 inches minimum and 1.545 inches maximum
-
Special Handling Feature
magnetic
-
Fragility Factor
moderately rugged
-
Thread Pitch In Millimeters
0.50
-
Arc Quenching Method
magnetic blowout
-
Special Features
actuator black with white markings; inertial delay included with item
-
Unpackaged Unit Weight
2.200 ounces
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Trip Release Characteristic
time delay single location
-
Nominal Thread Size
3.0 millimeters
-
Internal Trip Release Configuration
series trip single location
-
Manual Actuator Type And Quantity
1 toggle
-
Pole Quantity
1
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location
-
Switch Contact Arrangement
single pole, double throw
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.645 inches minimum and 1.675 inches maximum
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
-
Circuit Protection Type
overcurrent single location
-
Mounting Surface To Terminal End Distance
2.000 inches maximum
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct single location and 150.000 maximum at 200 pct single location
-
Mounting Facility Type And Quantity
2 threaded hole
-
Actuator Function
trip-reset
-
Storage Type
general purpose warehouse
-
Boss Height