441 4025

Circuit Breakers

CIRCUIT BREAKER

441 4025

5925-01-270-2735

5925 - Circuit Breakers

Koehring Cranes Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • End Item Identification

    3810-01-165-0647

  • Body Width

    0.560 inches nominal

  • Nominal Thread Size

    0.469 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct single location and 40.000 maximum at 200 pct single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc single location

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Mounting Surface To Terminal End Distance

    1.660 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Bushing Length

    0.300 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    0.840 inches nominal

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Terminal Type And Quantity

    2 tab w/screw

  • Storage Type

    general purpose warehouse

  • Manual Actuator Type And Quantity

    1 push button

  • Body Length

    1.380 inches nominal

  • Actuator Function

    reset

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...