ETN275210

Circuit Breakers

CIRCUIT BREAKER

ETN275210

5925-01-270-5250

5925 - Circuit Breakers

Spd Electrical Systems Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations and 10000.0 dc all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    150.000 nominal at 200 pct all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.625 inches nominal

  • Switch Terminal Type

    screw

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Internal Trip Release Configuration

    relay trip all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.750 inches nominal

  • Terminal Type And Quantity

    6 screw

  • Frequency In Hertz

    60.0 all locations or 400.0 all locations

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations and 50.0 amperes dc all locations

  • Boss Height

    0.188 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Body Height

    5.125 inches nominal

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Unthreaded Mounting Hole Diameter

    0.281 inches nominal

  • Switch Current Rating And Type In Amps

    50.0 ac and 50.0 dc

  • Arc Quenching Method

    air

  • Center To Center Distance Between Terminals Parallel To Length

    5.562 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Switch Voltage Rating And Type In Volts

    500.0 ac and 250.0 dc

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Body Length

    6.500 inches nominal

  • Actuator Position Designation

    at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    500.0 ac all locations and 250.0 dc all locations

  • Reset Method

    manual

  • Body Width

    4.125 inches nominal

  • Inclosure Protection Type For Which Designed

    dustproof

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...