711584-1

Circuit Breakers

CIRCUIT BREAKER

711584-1

5925-01-270-5258

5925 - Circuit Breakers

Raytheon Company

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Terminal Type And Quantity

    7 threaded stud

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Internal Trip Release Configuration

    shunt trip third location

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac third location and 240.0 ac third location

  • Body Length

    2.510 inches maximum

  • Manual Actuator Type And Quantity

    3 toggle

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Circuit Protection Type

    overcurrent second location

  • Thread Quantity Per Inch

    32

  • Body Width

    2.205 inches minimum and 2.285 inches maximum

  • Unpackaged Unit Weight

    0.547 pounds

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Internal Trip Release Configuration

    series trip first location

  • Mounting Surface To Terminal End Distance

    2.553 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Circuit Protection Type

    undervoltage third location

  • Internal Trip Release Configuration

    series trip second location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...