MIL-C-5809
Circuit Breakers
CIRCUIT BREAKER
MIL-C-5809
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performance
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.438 inches
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
thermal single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac single location
-
Manual Actuator Type And Quantity
1 push-pull
-
Center To Center Distance Between Terminals Parallel To Length
0.500 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.500 minimum at 200 pct single location and 40.000 maximum at 200 pct single location
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Inclosure Protection Type For Which Designed
shockproof and vibrationproof
-
Trip Release Ambient Temp Rating
121.0 deg celsius maximum single location
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Special Features
must have vibration test
-
Terminal Type And Quantity
2 tab w/screw
-
Body Length
0.781 inches maximum
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Actuator Function
trip-reset
-
Mounting Surface To Terminal End Distance
1.343 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac single location
-
Specification/Standard Data
96906-ms3320 government standard
-
Test Data Document
81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Thread Series Designator
un
-
Body Width
0.593 inches maximum
-
Case Material
plastic
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac single location
-
Bushing Length
0.250 inches nominal
-
Reset Method
manual
-
Actuator Position Designation
at pole one