3630-5114-01

Circuit Breakers

CIRCUIT BREAKER

3630-5114-01

5925-01-272-8157

5925 - Circuit Breakers

Unisys Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    1.844 inches minimum and 1.875 inches maximum

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Continuous Load Current Rating Per Pole

    120.0 amperes ac first location

  • Maximum Continuous Load Current Rating Per Pole

    7.0 amperes ac second location

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal and 2 threaded hole

  • Body Length

    1.469 inches minimum and 1.500 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Thread Series Designator

    unef and unc

  • Actuator Position Designation

    at pole two

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    7.0 amperes ac third location

  • Manual Actuator Type And Quantity

    1 toggle

  • Thread Quantity Per Inch

    32 and 32

  • Main Contact Tripping Mechanism Type

    trip free

  • Bushing Length

    0.349 inches minimum and 0.380 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.900 minimum at 200 pct all locations and 4.000 maximum at 200 pct all locations

  • Arc Quenching Method

    magnetic blowout

  • Frequency In Hertz

    400.0 all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and hermetically sealed and vibration resistant

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

  • Unpackaged Unit Weight

    5.400 ounces

  • Mounting Surface To Terminal End Distance

    1.749 inches minimum and 1.780 inches maximum

  • Nominal Thread Size

    0.375 inches and 0.138 inches

  • Terminal Type And Quantity

    6 wire hook

  • Nonturn Device Diameter

    0.235 inches minimum and 0.265 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Nonturn Device Radius

    0.610 inches minimum and 0.640 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...