Technical Characteristics
-
Contact Adjustability
actuation point adjustable
-
Temp Sensing Element Type
capillary tube-bulb
-
Mounting Method
bracket and unthreaded hole
-
Contact Voltage Rating In Volts
115.0 dc at sea level fifth voltage
-
Contact Voltage Rating In Volts
230.0 ac at sea level second voltage
-
Overall Width
2.812 inches nominal
-
Mounting Facility Pattern
isosceles triangle
-
Contact Load Current Rating
4.8 amperes inductive load sixth voltage
-
Contact Voltage Rating In Volts
550.0 ac at sea level fourth voltage
-
Unthreaded Mounting Hole Diameter
0.281 inches nominal
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
-
Hazardous Locations/Environmental Protection
watertight
-
Contact Voltage Rating In Volts
440.0 ac at sea level third voltage
-
Shortest Horizontal Distance Between Mounting Centers
0.656 inches nominal
-
Longest Horizontal Distance Between Mounting Centers
2.406 inches nominal
-
Contact Voltage Rating In Volts
550.0 dc at sea level eighth voltage
-
Contact Load Current Rating
3.2 amperes inductive load fourth voltage
-
Terminal Type
screw
-
Style Designator
rectangular
-
Contact Adjustment Type
internal actuation point screw
-
Contact Voltage Rating In Volts
440.0 dc at sea level seventh voltage
-
Media For Which Designed
gas or liquid
-
Contact Voltage Rating In Volts
115.0 ac at sea level first voltage
-
Contact Load Current Rating
9.6 amperes inductive load fifth voltage
-
Contact Load Current Rating
2.5 amperes inductive load seventh voltage
-
Operating Temp Rating
300.0 deg fahrenheit maximum
-
Contact Voltage Rating In Volts
230.0 dc at sea level sixth voltage
-
Contact Load Current Rating
2.0 amperes inductive load eighth voltage
-
Features Provided
electrical access port
-
Overall Height
6.250 inches nominal
-
Body Height
2.750 inches nominal
-
Longest Vertical Distance Between Mounting Centers
3.281 inches nominal
-
Contact Load Current Rating
8.0 amperes inductive load second voltage
-
Overall Length
5.188 inches nominal
-
Bulb Length
3.000 inches nominal
-
Capillary Tube Length
120.0 inches nominal
-
Bulb Diameter
0.375 inches nominal
-
Contact Load Current Rating
16.0 amperes inductive load first voltage
-
Contact Action Stimulus
increase
-
Contact Adjustment Range
+150.00/+225.00 actuation point degrees fahrenheit
-
Contact Load Current Rating
4.0 amperes inductive load third voltage