APGH9666-1REC4-21863-5

Circuit Breakers

CIRCUIT BREAKER

APGH9666-1REC4-21863-5

5925-01-275-2954

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac fourth location and 65.0 dc fourth location

  • Manual Actuator Type And Quantity

    4 toggle

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Switch Voltage Rating And Type In Volts

    240.0 ac and 50.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Boss Height

    0.130 inches nominal

  • Pole Quantity

    4

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Internal Trip Release Configuration

    relay trip fourth location

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac third location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Internal Trip Release Configuration

    series trip second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip third location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 1.900 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and moisture resistant and vibration resistant

  • Maximum Continuous Load Current Rating Per Pole

    12.5 amperes ac third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Unpackaged Unit Weight

    8.000 ounces

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac fourth location and 1000.0 dc fourth location

  • Circuit Protection Type

    overcurrent first location

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Body Width

    3.015 inches maximum

  • Switch Current Rating And Type In Amps

    5.0 ac and 3.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac fourth location and 15.0 amperes dc fourth location

  • Circuit Protection Type

    overcurrent second location

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    12.5 amperes ac first location

  • Circuit Protection Type

    undervoltage fourth location

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Circuit Protection Type

    overcurrent third location

  • Internal Trip Release Configuration

    series trip first location

  • Maximum Continuous Load Current Rating Per Pole

    12.5 amperes ac second location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Switch Contact Arrangement

    single pole, double throw

  • Terminal Type And Quantity

    8 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...