JA2-A0.05A15-A-P-2

Circuit Breakers

CIRCUIT BREAKER

JA2-A0.05A15-A-P-2

5925-01-275-6431

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Surface To Terminal End Distance

    2.210 inches nominal

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Trip Release Characteristic

    instantaneous all locations

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Internal Trip Release Configuration

    series trip w/auxiliary load terminal second location

  • Terminal Type And Quantity

    7 quick disconnect, male

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    32.0 dc nominal first location

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Internal Trip Release Configuration

    series/relay trip first location

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.860 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • End Item Identification

    support equipment b-1 aircraft. c-5 galaxy aircraft.

  • Center To Center Distance Between Terminals Parallel To Length

    1.560 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and moisture resistant and vibration resistant

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Trip Release Duty Cycle

    continuous first location

  • Body Width

    1.500 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Case Material

    plastic

  • Boss Height

    0.130 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...