219-2-1-63F-5-8-9

Circuit Breakers

CIRCUIT BREAKER

219-2-1-63F-5-8-9

5925-01-276-3749

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    2.067 inches minimum and 2.072 inches maximum

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Maximum Continuous Load Current Rating Per Pole

    9.0 amperes ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Surface To Terminal End Distance

    3.545 inches minimum and 3.555 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Center To Center Distance Between Terminals Parallel To Length

    3.545 inches minimum and 2.555 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.021 inches minimum and 1.031 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Boss Height

    0.215 inches minimum and 0.225 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.745 inches minimum and 2.755 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct all locations and 130.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Center To Center Distance Between Terminals Parallel To Width

    1.021 inches minimum and 1.031 inches maximum

  • Body Length

    5.120 inches minimum and 5.130 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    277.0 ac all locations and 480.0 ac all locations

  • Terminal Type And Quantity

    4 threaded stud

  • External Actuator Linkage Arrangement

    one and two linked

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...