024-23781

Circuit Breakers

CIRCUIT BREAKER

024-23781

5925-01-277-0674

5925 - Circuit Breakers

York International Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Terminal Type And Quantity

    2 wire hook

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Unpackaged Unit Weight

    1.800 ounces

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location

  • Pole Quantity

    1

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shockproof and vibrationproof

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Body Length

    1.562 inches maximum

  • Body Style

    single pole type

  • Body Width

    0.625 inches maximum

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Thread Series Designator

    unef

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct single location and 0.700 maximum at 200 pct single location

  • Bushing Length

    0.380 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...