APGN-6-1-42-103

Circuit Breakers

CIRCUIT BREAKER

APGN-6-1-42-103

5925-01-277-6031

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    400.0 single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2100.0 ac single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Bushing Length

    0.625 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Thread Pitch Diameters

    +0.4752/+0.4787 inches

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Pole Quantity

    1

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Nonturn Device Location

    at 12 oclock

  • Body Length

    2.000 inches nominal

  • Actuator Function

    trip-reset

  • Body Width

    0.750 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Nominal Thread Size

    0.500 inches

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

  • Nonturn Device Length

    0.130 inches nominal

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Nonturn Device Radius

    0.656 inches nominal

  • Thread Series Designator

    un

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct single location and 25.000 maximum at 200 pct single location

  • Unpackaged Unit Weight

    3.000 ounces

  • Terminal Type And Quantity

    2 tab w/screw

  • Trip Release Method

    magnetic-hydraulic single location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...