6900-0088-008

Circuit Breakers

CIRCUIT BREAKER

6900-0088-008

5925-01-277-6033

5925 - Circuit Breakers

Antenna Products Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.650 inches minimum and 1.670 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    12.000 minimum at 200 pct all locations and 55.000 maximum at 200 pct all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Mounting Surface To Terminal End Distance

    1.950 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.550 inches minimum and 1.570 inches maximum

  • Case Material

    plastic

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Body Length

    1.990 inches minimum and 2.010 inches maximum

  • Terminal Type And Quantity

    6 tab, solder lug

  • Storage Type

    general purpose warehouse

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Arc Quenching Method

    air

  • Body Style

    multipole-multiple actuator type

  • Boss Height

    0.120 inches minimum and 0.140 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Width

    2.240 inches minimum and 2.260 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...