538115-11

Relays and Solenoids

RELAY,ELECTROMAGNETIC

538115-11

5945-01-278-9034

5945 - Relays and Solenoids

Raytheon Company

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • ~1

    data on certain environmental and performance

  • Test Data Document

    81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Main Contact Load Current Rating At Maximum Rated Voltage

    4.0 amperes dc motor load

  • Overall Height

    1.010 inches maximum

  • Storage Type

    general purpose warehouse

  • Operating Voltage Rating And Type At Specified Temp

    115.0 volts ac 25 deg celsius single winding

  • Environmental Protection

    hermetic

  • Mounting Slot Width

    0.150 inches nominal single mounting facility

  • Specification/Standard Data

    96906-ms27400 government standard

  • Winding Quantity

    1

  • Overall Length

    1.718 inches maximum

  • Mounting Facility Type And Quantity

    3 slotted hole single mounting facility

  • Case Material

    metal

  • Frequency In Hertz

    400.0 nominal

  • Mounting Facility Pattern

    triangle single mounting facility

  • Nonpile-Up Main Contact Arrangement

    4 pole, double throw, one position momentary

  • Main Contact Load Current Rating At Maximum Rated Voltage

    8.0 amperes dc inductive load

  • Purpose For Which Designed

    general

  • Overall Width

    1.025 inches maximum

  • Coil Quantity

    1

  • Main Contact Maximum Voltage Rating In Volts

    28.0 dc

  • Cubic Measure

    1.778 cubic inches

  • Main Contact Load Current Rating At Maximum Rated Voltage

    10.0 amperes dc resistive load

  • Main Contact Load Current Rating At Maximum Rated Voltage

    2.0 amperes dc lamp load

  • Time Delay

    0.05 seconds maximum fixed release time

  • Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle

    1.446 inches nominal single mounting facility

  • Duty Type

    continuous

  • Time Delay

    0.02 seconds maximum fixed operate time

  • Terminal Type And Quantity

    14 wire hook all functions

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    0.625 inches nominal single mounting facility

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...