C5108036-1

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

C5108036-1

5915-01-279-0042

5915 - Filters and Networks

Signals Warfare Project Manager

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Voltage Drop Per Function

    0.25 volts dc 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Body Surface Treatment

    tin

  • Features Provided

    shock resistant

  • Vibration Resistance Range In Hertz

    +10.0/+2000.0

  • Operating Current Rating Per Function In Amps

    10.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    10.0 4th radio interference

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle input 1st function

  • Body Length

    2.800 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Operating Current Rating Per Function In Amps

    10.0 5th radio interference

  • Operating Current Rating Per Function In Amps

    10.0 6th radio interference

  • Input Terminal Identification

    ms27508e22f21p

  • Functional Terminal Type And Quantity

    11 tab, solder lug output 2nd function

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 2nd radio interference 2nd function

  • Maximum Voltage Drop Per Function

    0.08 volts dc 1st radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Maximum Dielectric Withstanding Dc Voltage

    500.0 volts at sea level

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.100 inches nominal

  • Maximum Voltage Drop Per Function

    0.08 volts dc 2nd radio interference

  • Nominal Thread Size

    0.138 inches

  • End Item Identification

    5865-01-262-7031 communication p

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Mounting Facility Screw Thread Series Designator

    unc

  • Input Terminal Manufacturer Code

    96906

  • Body Width

    1.820 inches nominal

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 3rd radio interference 3rd function

  • Operating Current Rating Per Function In Amps

    20.0 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Maximum Voltage Drop Per Function

    0.25 volts dc 4th radio interference

  • Operating Current Rating Per Function In Amps

    20.0 1st radio interference

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 4th radio interference 4th function

  • Maximum Voltage Drop Per Function

    0.25 volts dc 5th radio interference

  • Functional Terminal Type And Quantity

    8 turret ground 3rd function

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Body Height

    2.500 inches nominal

  • Maximum Voltage Drop Per Function

    0.25 volts dc 6th radio interference

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 5th radio interference 5th function

  • Operating Voltage Rating And Type Per Function

    100.0 volts dc 6th radio interference 6th function

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Maximum Temp Rise

    20.0 deg celsius

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Temp Range

    -55.0/+85.0 deg celsius

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 1st radio interference 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Unpackaged Unit Weight

    4.000 pounds

  • Inclosure Type

    encased

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...