331033P05
Switches
SWITCH,PRESSURE
331033P05
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Hazardous Locations/Environmental Protection
vibration resistant
-
Mounting Method
input port
-
Contact Action Stimulus
increase
-
Proof Pressure
450.00 pounds per square inch gage
-
Nominal Thread Size
0.438 inches single pressure connection
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Terminal Type
connector, receptacle
-
Style Designator
41 cylindrical
-
Media For Which Designed
liquid
-
Pressure Connector Type
flared, threaded external single connection
-
Contact Stimulus Rating
42.10 actuation point nominal pounds per square inch absolute and 32.10 deactuat
-
Contact Load Current Rating
1.2 amperes resistive load and 660.0 milliamperes inductive load single voltage
-
Sensing Element Burst Pressure
1200.00 pounds per square inch gage
-
Width Across Flats
0.680 inches nominal
-
Pressure Switch Type
absolute
-
Overall Diameter
0.880 inches nominal
-
Outside Diameter
0.438 inches nominal single connection
-
Overall Length
3.120 inches maximum
-
Thread Class
3a single pressure connection
-
Thread Series Designator
unf single pressure connection
-
Contact Voltage Rating In Volts
28.0 dc at sea level single voltage
-
~1
ion point nominal pounds per square inch absolute
-
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable