PR11-2-5.00A-XX

Circuit Breakers

CIRCUIT BREAKER

PR11-2-5.00A-XX

5925-01-282-0019

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Function

    reset

  • Fragility Factor

    moderately rugged

  • Inclosure Protection Type For Which Designed

    dustproof

  • Case Material

    plastic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location and 1000.0 dc single location

  • Storage Type

    general purpose warehouse

  • Manual Actuator Type And Quantity

    1 push button

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Mounting Surface To Terminal End Distance

    1.930 inches minimum and 1.990 inches maximum

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    5.000 amperes ac single location and 5.000 amperes dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Body Width

    0.650 inches minimum and 0.670 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    1.095 inches minimum and 1.155 inches maximum

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Bushing Length

    0.390 inches minimum and 0.410 inches maximum

  • Terminal Type And Quantity

    2 tab, solder lug

  • Body Style

    single pole type

  • Body Length

    1.365 inches minimum and 1.385 inches maximum

  • Trip Release Method

    magnetic-hydraulic single location

  • Thread Series Designator

    unef

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 50.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...