1810546
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
1810546
Northrop Grumman Systems Corporation
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Type
encased
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.923 inches minimum and 2.953 inches maximum
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Operating Current Rating Per Function In Amps
2.0 2nd radio interference
-
Body Width
2.070 inches maximum
-
Overall Length
10.560 inches nominal
-
Functional Terminal Type And Quantity
1 wire lead ground 3rd function
-
Body Material
metal
-
Functional Terminal Type And Quantity
2 wire lead output 2nd function
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
End Item Identification
4935-01-142-3733 test position,s
-
Functional Terminal Type And Quantity
2 wire lead input 1st function
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 1st radio interference 1st function
-
Power Line Frequency Rating Per Function In Hertz
50.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance-resistance 2nd radio interference
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 2nd radio interference 2nd function
-
Operating Current Rating Per Function In Amps
2.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
50.0 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Body Height
1.780 inches maximum
-
Maximum Dielectric Withstanding Dc Voltage
2.25 kilovolts at sea level
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Principal Circuitry Type Per Function
inductance-capacitance-resistance 1st radio interference
-
Body Length
2.560 inches maximum
-
Unthreaded Mounting Hole Diameter
0.188 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference