AM2-B3A3-A-P1-15A-65VDC-2/P2-15A

Circuit Breakers

CIRCUIT BREAKER

AM2-B3A3-A-P1-15A-65VDC-2/P2-15A

5925-01-283-4243

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc first location

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one and two linked

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 22.000 maximum at 200 pct second location

  • Frequency In Hertz

    60.0 second location

  • Thread Series Designator

    unc

  • Thread Pitch Diameters

    0.1177 to 0.1214 inches

  • Body Width

    1.515 inches minimum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.745 inches minimum and 0.755 inches maximum

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.930 inches minimum and 1.950 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.045 inches minimum and 2.075 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Pole Quantity

    2

  • Iii Arc Quenching Method

    magnetic blowout

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac second location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc first location

  • Mounting Surface To Terminal End Distance

    2.797 inches minimum and 2.827 inches maximum

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc first location

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.650 minimum at 200 pct and 10.000 maximum at 200 pct first location

  • Inclosure Protection Type For Which Designed

    dustproof

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...