B110930
Coils and Transformers
TRANSFORMER,POWER
B110930
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Rating
47.0 hertz minimum and 67.0 hertz maximum single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Body Width
3.250 inches maximum
-
Body Height
2.781 inches minimum and 2.843 inches maximum
-
Mounting Method
bracket and unthreaded hole single group
-
Winding Function And Quantity
1 primary and 1 secondary single component
-
Winding Operating Current
100.0 milliamperes dc maximum single component 1st secondary
-
Winding Operating Current
4.0 amperes dc maximum single component 2nd secondary
-
Winding Operating Voltage
103.50 ac volts minimum and 126.50 ac volts maximum single component single prim
-
Winding Operating Voltage
25.00 dc volts nominal single component 1st secondary
-
Cognizant Service
usaf
-
Terminal Type And Quantity
2 tab, solder lug and 5 wire lead
-
Reliability Indicator
not established
-
~1
nter group
-
~1
nter group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.781 inches minimum and 1.843 inches maximum single mounting facility single ce
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.172 inches minimum and 2.204 inches maximum single mounting facility single ce
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Body Length
3.344 inches minimum and 3.406 inches maximum
-
End Item Identification
4920-01-111-2981
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4 single group
-
Winding Tap Location
center tap single component 1st secondary
-
~1
ary
-
Winding Operating Voltage
18.50 dc volts nominal single component 2nd secondary