C16478
Coils and Transformers
TRANSFORMER,POWER
C16478
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Maximum Operating Temp
130.0 deg celsius
-
Frequency Rating
60.0 hertz nominal single component
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Current
1.0 amperes ac nominal single component 4th secondary
-
Reliability Indicator
not established
-
Features Provided
color coded lead
-
Winding Operating Current
1.0 amperes ac nominal single component 3rd secondary
-
Winding Power Rating
25.0 volts-amperes single component 3rd secondary
-
Winding Operating Voltage
14.78 ac volts nominal single component 4th secondary
-
Mounting Method
unthreaded hole single group
-
Winding Shielding Method
internal shield grounded to inclosure and brought out to terminal single component
-
Center To Center Distance Between Mounting Facilities Parallel To Width
3.050 inches nominal single mounting facility single center group
-
Winding Operating Current
8.0 amperes ac nominal single component 2nd secondary
-
Special Features
1 primary winding; 6 secondary windings
-
Winding Operating Current
8.0 amperes ac nominal single component 1st secondary
-
Overall Length
4.500 inches minimum and 4.560 inches maximum
-
Mounting Hole Diameter
0.208 inches minimum single group and 0.228 inches maximum single group
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.780 inches nominal single mounting facility single center group
-
Winding Function And Quantity
1 primary single component and 6 secondary single component
-
Inclosure Type
open
-
Winding Operating Voltage
11.89 ac volts nominal single component 2nd secondary
-
Overall Width
3.770 inches minimum and 3.830 inches maximum
-
Winding Power Rating
14.8 volts-amperes single component 4th secondary
-
Terminal Type And Quantity
3 tab, solder lug and 12 wire lead
-
Winding Power Rating
95.1 volts-amperes single component 2nd secondary
-
Mounting Facility Quantity
4 single group
-
Winding Power Rating
95.1 volts-amperes single component 1st secondary
-
Winding Operating Voltage
11.89 ac volts nominal single component 1st secondary
-
Test Data Document
73030-sv798894 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
-
Winding Operating Voltage
106.95 ac volts minimum single component single primary and 123.05 ac volts maximum single component single primary
-
Body Height
4.400 inches maximum
-
Winding Operating Voltage
24.95 ac volts nominal single component 3rd secondary