WF1814/58-D5090
Fuses, Arrestors, Absorbers, and Protectors
FUSE,CARTRIDGE
WF1814/58-D5090
5920 - Fuses, Arrestors, Absorbers, and Protectors
FUSE,CARTRIDGE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Case Material
ceramic or fiber or plastic, melamine, glass filled
-
Body Length
3.375 inches minimum and 3.781 inches maximum
-
Overall Diameter
1.310 inches maximum
-
Body Style
axial terminal type
-
Short-Circuit/Interrupt Current Rating In Amps
200000.0
-
Terminal Thickness
0.122 inches minimum and 0.128 inches maximum
-
Overall Length
5.820 inches minimum and 5.940 inches maximum
-
Continuous Current Rating In Amps
90.000
-
Terminal Material
copper or copper alloy
-
Terminal Width
0.715 inches minimum and 0.785 inches maximum
-
Circuit Over-Current Interruption Delay Time In Seconds
10.0 500 pct of current rating
-
Mounting Slot Width
0.276 inches minimum and 0.306 inches maximum
-
Maximum Voltage Rating In Volts
250.0 ac
-
Specification/Standard Data
81348-w-f-1814/58 government specification
-
Interruption Indicator Method
opaque body
-
Test Data Document
81348-w-f-1814 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performance r
-
Fragility Factor
moderately rugged
-
Features Provided
nonrenewable fusible element
-
Circuit Over-Current Interruption Type
time delay
-
Terminal Surface Treatment
solder dip