170545-001

Circuit Breakers

CIRCUIT BREAKER

170545-001

5925-01-285-2046

5925 - Circuit Breakers

Harris Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.480 inches minimum and 2.520 inches maximum

  • Body Width

    1.480 inches minimum and 1.520 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.918 inches minimum and 1.958 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.042 inches minimum and 2.082 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.730 inches minimum and 0.770 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.120 inches minimum and 0.160 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Terminal Type And Quantity

    4 threaded stud

  • Body Style

    8c multipole-multiple actuator type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.730 inches minimum and 0.770 inches maximum

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.501 inches maximum

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 20.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Frequency In Hertz

    50.0 or 60.0

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...