2131850-28

Circuit Breakers

CIRCUIT BREAKER

2131850-28

5925-01-285-8028

5925 - Circuit Breakers

Honeywell Intl Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Nonturn Device Length

    0.135 inches minimum and 0.145 inches maximum

  • Nonturn Device Diameter

    0.245 inches minimum and 0.255 inches maximum

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc second location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc third location

  • Maximum Continuous Load Current Rating Per Pole

    7.0 amperes ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc third location

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct all locations and 0.700 maximum at 200 pct

  • Frequency In Hertz

    50.0 first location or 60.0

  • Unpackaged Unit Weight

    3.600 ounces

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 wire hook

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Body Style

    1b multipole-single actuator type

  • Bushing Length

    0.380 inches maximum

  • Body Length

    1.500 inches maximum

  • Body Width

    1.875 inches maximum

  • Nonturn Device Radius

    0.620 inches minimum and 0.630 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc second location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc third location

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shockproof and vibrationproof

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...