AM4-A3A3A3A0-50-250-2

Circuit Breakers

CIRCUIT BREAKER

AM4-A3A3A3A0-50-250-2

5925-01-287-4283

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 second location

  • Internal Trip Release Configuration

    series trip third location

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Width

    0.722 inches minimum and 0.782 inches maximum

  • Trip Release Method

    magnetic-hydraulic first location

  • Boss Height

    0.140 inches minimum and 0.172 inches maximum

  • Trip Release Characteristic

    time delay third location

  • Center To Center Distance Between Terminals Parallel To Length

    1.906 inches minimum and 1.970 inches maximum

  • Body Width

    2.968 inches minimum and 3.032 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 third location

  • Frequency In Hertz

    60.0 third location

  • Mounting Surface To Terminal End Distance

    2.688 inches minimum and 2.752 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct third location and 20.000 maximum at 200 pct third location

  • Trip Release Method

    magnetic-hydraulic second location

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac first location

  • Trip Release Method

    magnetic-hydraulic third location

  • Inclosure Protection Type For Which Designed

    humidity resistant and moisture resistant and fungus resistant and shock resistant and vibration resistant

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Manual Actuator Type And Quantity

    4 toggle

  • Frequency In Hertz

    50.0 fourth location or 60.0 fourth location

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Switch Terminal Type

    threaded stud

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent first location

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct first location and 20.000 maximum at 200 pct first location

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac third location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Body Length

    2.468 inches minimum and 2.532 inches maximum

  • Circuit Protection Type

    overcurrent second location

  • Switch Current Rating And Type In Amps

    50.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac third location

  • Case Material

    plastic

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac second location

  • Pole Quantity

    4

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.030 inches minimum and 2.094 inches maximum

  • Thread Quantity Per Inch

    32

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.722 inches minimum and 0.782 inches maximum

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Frequency In Hertz

    60.0 first location

  • Body Style

    multipole-multiple actuator type

  • Circuit Protection Type

    overcurrent third location

  • Frequency In Hertz

    60.0 second location

  • Internal Trip Release Configuration

    series trip first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 first location

  • Trip Release Characteristic

    time delay first location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Switch Contact Arrangement

    single pole, double throw

  • Special Features

    fourth pole is switch only

  • Terminal Type And Quantity

    8 threaded stud

  • Unpackaged Unit Weight

    9.500 ounces

  • Internal Trip Release Configuration

    series trip second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac third location

  • Switch Location And Position Designation

    external at pole four

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct second location and 20.000 maximum at 200 pct second location

  • Trip Release Characteristic

    time delay second location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...